A novel closed-loop electromechanical stimulator to enhance osseointegration with immediate loading of dental implant restorations

I M Meswania, V A Bousdras, S P Ahir, J L Cunningham, G W Blunn, A E Goodship

    Research output: Contribution to journalArticlepeer-review

    Abstract

    The degree of osseomechanical integration of dental implants is acutely sensitive to their mechanical environment. Bone, both as a tissue and structure, adapts its mass and architecture in response to loading conditions. Therefore, application of predefined controlled loads may be considered as a treatment option to promote early maturation of bone/implant interface prior to or in conjunction with crown/prosthesis attachment. Although many studies have established that the magnitude, rate of the applied strain, and frequency have significant effects on the osteogenic response, the actual specific relationships between strain parameters and frequency have not yet been fully defined. The purpose of this study was to develop a stimulator to apply defined mechanical stimuli to individual dental implants in vivo immediately after implantation, exploring the hypothesis that immediate controlled loading could enhance implant integration. An electromechanical device was developed, based on load values obtained using a two-dimensional finite element analysis of the bone/implant interface generating 1000 to 4000 pe and operated at 30 and 3 Hz respectively. The device was then tested in a cadaveric pig mandible, and periosteal bone surface strains were recorded for potential future comparison with a three-dimensional finite element model to determine loading regimens to optimize interface strains and iterate the device for clinical use.

    Original languageEnglish
    Pages (from-to)1221-31
    Number of pages10
    JournalProceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine
    Volume224
    Issue number10
    DOIs
    Publication statusPublished - Oct 2010

    Keywords

    • Animals
    • Biomechanical Phenomena
    • Dental Implants
    • Dental Restoration, Permanent
    • Finite Element Analysis
    • Osseointegration
    • Physical Stimulation
    • Stress, Mechanical
    • Swine
    • Research Support, Non-U.S. Gov't

    Fingerprint

    Dive into the research topics of 'A novel closed-loop electromechanical stimulator to enhance osseointegration with immediate loading of dental implant restorations'. Together they form a unique fingerprint.

    Cite this