Effect of curing cycle on the tensile strength of the bond between heat cured denture base acrylic resin and acrylic resin denture teeth

Ayesha Dalal*, Andrzej S. Juszczyk, David R. Radford, Robert K. F. Clark

*Corresponding author for this work

    Research output: Contribution to journalArticlepeer-review

    Abstract

    The effect of different curing cycles on the tensile strength of the bond between one brand of cross-linked acrylic resin teeth and three heat cured denture base acrylic resins was tested. There were differences in the tensile bond strength between the three heat cured denture base acrylic resins and the three curing cycles used. The bond strength of the acrylic resin denture base material made by the same manufacturer as the cross-linked acrylic resin denture teeth was higher. The bond strength following the short cycle was lowest in all cases, individual differences between curing cycles failed to reach statistical significance.

    Original languageEnglish
    Pages (from-to)146-149
    JournalEuropean Journal of Prosthodontics and Restorative Dentistry
    Volume17
    Issue number4
    Publication statusPublished - Dec 2009

    Fingerprint

    Dive into the research topics of 'Effect of curing cycle on the tensile strength of the bond between heat cured denture base acrylic resin and acrylic resin denture teeth'. Together they form a unique fingerprint.

    Cite this