TY - JOUR
T1 - Finite element analysis of a hemi-pelvis
T2 - the effect of inclusion of cartilage layer on acetabular stresses and strain
AU - Ghosh, Rajesh
AU - Pal, Bidyut
AU - Ghosh, Debatri
AU - Gupta, Sanjay
PY - 2015
Y1 - 2015
N2 - An appropriate method of application of the hip-joint force and stress analysis of the pelvic bone, in particular the acetabulum, is necessary to investigate the changes in load transfer due to implantation and to calculate the reference stimulus for bone remodelling simulations. The purpose of the study is to develop a realistic 3D finite element (FE) model of the hemi-pelvis and to assess stress and strain distribution during a gait cycle. The FE modelling approach of the pelvic bone was based on CT scan data and image segmentation of cortical and cancellous bone boundaries. Application of hip-joint force through an anatomical femoral head having a cartilage layer was found to be more appropriate than a perfectly spherical head, thereby leading to more accurate stress–strain distribution in the acetabulum. Within the acetabulum, equivalent strains varied between 0.1% and 0.7% strain in the cancellous bone. High compressive (15–30 MPa) and low tensile (0–5 MPa) stresses were generated within the acetabulum. The hip-joint force is predominantly transferred from the acetabulum through the lateral cortex to the sacroiliac joint and the pubic symphysis. The study is useful to understand the load transfer within the acetabulum and for further investigations on acetabular prosthesis.
AB - An appropriate method of application of the hip-joint force and stress analysis of the pelvic bone, in particular the acetabulum, is necessary to investigate the changes in load transfer due to implantation and to calculate the reference stimulus for bone remodelling simulations. The purpose of the study is to develop a realistic 3D finite element (FE) model of the hemi-pelvis and to assess stress and strain distribution during a gait cycle. The FE modelling approach of the pelvic bone was based on CT scan data and image segmentation of cortical and cancellous bone boundaries. Application of hip-joint force through an anatomical femoral head having a cartilage layer was found to be more appropriate than a perfectly spherical head, thereby leading to more accurate stress–strain distribution in the acetabulum. Within the acetabulum, equivalent strains varied between 0.1% and 0.7% strain in the cancellous bone. High compressive (15–30 MPa) and low tensile (0–5 MPa) stresses were generated within the acetabulum. The hip-joint force is predominantly transferred from the acetabulum through the lateral cortex to the sacroiliac joint and the pubic symphysis. The study is useful to understand the load transfer within the acetabulum and for further investigations on acetabular prosthesis.
U2 - 10.1080/10255842.2013.843674
DO - 10.1080/10255842.2013.843674
M3 - Article
SN - 1025-5842
VL - 18
SP - 697
EP - 710
JO - Computer Methods in Biomechanics and Biomedical Engineering
JF - Computer Methods in Biomechanics and Biomedical Engineering