Headspace solid-phase microextraction with 1-pyrenyldiazomethane on-fibre derivatisation for analysis of fluoroacetic acid in biological samples

F. Sporkert, F. Pragst, S. Hubner, Graham Mills

    Research output: Contribution to journalArticlepeer-review

    Abstract

    A new and in part automated headspace solid-phase microextraction method for quantitative determination of the highly toxic rodenticide fluoroacetic acid (FAA) in serum and other biological samples has been developed. FAA and deuterated acetic acid (internal standard) were extracted from acidified samples by a StableFlex divinylbenzene–Carboxen on polydimethylsiloxane fibre. The acids were derivatised on the fibre in-situ with 1-pyrenyldiazomethane and detected using gas chromatography–mass spectrometry with electron impact ionisation and selected ion monitoring. The calibration curve for FAA in serum was linear over the range from 0.02 to 5 μg/ml, with limits of detection and quantification of 0.02 and 0.07 μg/ml, respectively. The method was also tested with spiked whole blood, urine, stomach contents and kidney samples. It was sufficiently reliable, reproducible and sensitive for use in routine forensic toxicology applications.
    Original languageEnglish
    Pages (from-to)45-51
    Number of pages7
    JournalJournal of Chromatography B
    Volume772
    Issue number1
    DOIs
    Publication statusPublished - 25 May 2002

    Fingerprint

    Dive into the research topics of 'Headspace solid-phase microextraction with 1-pyrenyldiazomethane on-fibre derivatisation for analysis of fluoroacetic acid in biological samples'. Together they form a unique fingerprint.

    Cite this