Quantification of human bone microarchitecture damage in press-fit femoral knee implantation using HR-pQCT and digital volume correlation

Sophie Rapagna, Sanaz Berahmani, Caroline Wyers, Joop van den Bergh, Karen Reynolds, Gianluca Tozzi, Dennis Janssen, Egon Perilli

Research output: Contribution to journalArticlepeer-review

167 Downloads (Pure)

Abstract

Primary press-fit fixation of femoral knee prostheses is obtained thanks to the inside dimensions of the implant being undersized with respect to the bone cuts created intra-operatively, dictated by a press-fit specified by the implant design. However, during prostheses press-fit implantation, high compressive and shear stresses at the implant-bone interface are generated which causes permanent bone damage. The extent of this damage is unknown, but it may influence the implant stability and be a contributing factor to aseptic loosening, a main cause of revisions for knee arthroplasty. The aim of this ex-vivo study was to quantify, using high-resolution peripheral quantitative computed tomography (HR-pQCT) imaging and Digital Volume Correlation (DVC), permanent bone deformation due to press-fit femoral knee implantation using a commonly used implant. Six human cadaveric distal femora were resected and imaged with HR-pQCT (60.7 µm/voxel, isotropic). Femurs were fitted with cementless femoral knee implants (Sigma PFC) and rescanned after implant removal. For each femur, permanent deformation was examined in the anterior, posterior-medial and posterior-lateral condyles for volumes of interest (VOIs) of 10 mm depth. The bone volume fraction (BV/TV) for the VOIs in pre- and post-implantation images was calculated, at increasing depth from the bone surface. DVC was applied on the VOIs pre- and post-implantation, to assess trabecular bone displacements and plastically accumulated strains. The “BV/TVpost/BV/TVpre ratio vs. depth” showed, consistently among the six femurs, three consecutive points of interest at increasing bone depth, indicating: bone removal (ratio<100%), compaction (ratio>100%) and no changes (ratio=100%). Accordingly, the trabecular bone displacement computed by DVC suggested bone compaction up to 2.6±0.8 mm in depth, with peak third principal strains of -162,100±55,000 µε (mean absolute error: 1,000-2,000 µε, SD: 200-500 µε), well above the yield strain of bone (7,000-10,000 µε). Combining 3D-imaging, at spatial resolutions obtainable with clinical HR-pQCT, and DVC, determines the extent of plastic deformation and accumulated compressive strains occurring within the bone due to femoral press-fit implantation. The methods and data presented can be used to compare different implants, implant surface coatings and press-fit values. These can also be used to advance and validate computational models by providing information about the bone-implant interface obtained experimentally. Future studies using these methods can assist in determining the influence of bone damage on implant stability and the subsequent osseointegration.
Original languageEnglish
Pages (from-to)278-287
Number of pages10
JournalJournal of the Mechanical Behavior of Biomedical Materials
Volume97
Early online date4 May 2019
DOIs
Publication statusPublished - 1 Sept 2019

Fingerprint

Dive into the research topics of 'Quantification of human bone microarchitecture damage in press-fit femoral knee implantation using HR-pQCT and digital volume correlation'. Together they form a unique fingerprint.

Cite this