The effect of particle size on the osteointegration of injectable silicate-substituted calcium phosphate bone substitute materials

Melanie J Coathup, Qian Cai, Charlie Campion, Thomas Buckland, Gordon W Blunn

Research output: Contribution to journalArticlepeer-review

Abstract

Calcium phosphate (CaP) particles as a carrier in an injectable bone filler allows less invasive treatment of bony defects. The effect of changing granule size within a poloxamer filler on the osteointegration of silicate-substituted calcium phosphate (SiCaP) bone substitute materials was investigated in an ovine critical-sized femoral condyle defect model. Treatment group (TG) 1 consisted of SiCaP granules sized 1000-2000 μm in diameter (100 vol %). TG2 investigated a granule size of 250-500 μm (75 vol %), TG3 a granule size of 90-125 μm (75 vol %) and TG4 a granule size of 90-125 μm (50 vol %). Following a 4 and 8 week in vivo period, bone area, bone-implant contact, and remaining implant area were quantified within each defect. At 4 weeks, significantly increased bone formation was measured in TG2 (13.32% ± 1.38%) when compared with all other groups (p = 0.021 in all cases). Bone in contact with the bone substitute surface was also significantly higher in TG2. At 8 weeks most new bone was associated within defects containing the smallest granule size investigated (at the lower volume) (TG4) (42.78 ± 3.36%) however this group was also associated with higher amounts of fragmented SiCaP. These smaller particles were phagocytosed by macrophages and did not appear to have a negative influence on healing. In conclusion, SiCaP granules of 250-500 μm in size may be a more suitable scaffold when used as an injectable bone filler and may be a convenient method for treating bony defects.

Original languageEnglish
Pages (from-to)902-10
Number of pages9
JournalJournal of Biomedical Materials Research - Part B Applied Biomaterials
Volume101
Issue number6
DOIs
Publication statusPublished - Aug 2013

Keywords

  • Animals
  • Bone Regeneration
  • Bone Substitutes
  • Calcium Phosphates
  • Female
  • Femur
  • Injections
  • Materials Testing
  • Microscopy, Electron, Scanning
  • Models, Animal
  • Osseointegration
  • Particle Size
  • Poloxamer
  • Sheep, Domestic
  • Silicates
  • Tissue Scaffolds

Fingerprint

Dive into the research topics of 'The effect of particle size on the osteointegration of injectable silicate-substituted calcium phosphate bone substitute materials'. Together they form a unique fingerprint.

Cite this