Abstract

Digital volume correlation (DVC) in combination with high-resolution micro-computed tomography (microCT) imaging and in situ mechanical testing is gaining popularity for quantifying 3D full-field strains in bone and biomaterials. However, traditional in situ time-lapsed (i.e., interrupted) mechanical testing cannot fully capture the dynamic strain mechanisms in viscoelastic biological materials. The aim of this study was to investigate the time-resolved deformation of bone structures and analogues via continuous in situ synchrotron-radiation microCT (SR-microCT) compression and DVC to gain a better insight into their structure-function relationships. Fast SR-microCT imaging enabled the deformation behaviour to be captured with high temporal and spatial resolution. Time-resolved DVC highlighted the relationship between local strains and damage initiation and progression in the different biostructures undergoing plastic deformation, bending and/or buckling of their main microstructural elements. The results showed that SR-microCT continuous mechanical testing complemented and enhanced the information obtained from time-lapsed testing, which may underestimate the 3D strain magnitudes as a result of the stress relaxation occurring in between steps before image acquisition in porous biomaterials. Altogether, the findings of this study highlight the importance of time-resolved in situ experiments to fully characterise the time-dependent mechanical behaviour of biological tissues and biomaterials and to further explore their micromechanics under physiologically relevant conditions.
Original languageEnglish
Pages (from-to)424-439
JournalActa Biomaterialia
Volume131
Early online date12 Jun 2021
DOIs
Publication statusPublished - 1 Sept 2021

Keywords

  • bone
  • time-resolved SR-microCT
  • continuous in situ mecahnics
  • digital volume correlation
  • time-dependent behaviour

Fingerprint

Dive into the research topics of 'Time-resolved in situ synchrotron-microCT: 4D deformation of bone and bone analogues using digital volume correlation'. Together they form a unique fingerprint.

Cite this