Investigation of haemodynamic markers for stenosis development

Research output: Contribution to journalArticlepeer-review

Different haemodynamic markers for stenosis development are considered, assessed and compared. A recently proposed numerical approach is employed, where stenosis development is modelled based on the local haemodynmaic conditions at the artery wall, determined using the lattice Boltzmann method. A range of haemodynamic markers, commonly associated in the literature with the progression of atherosclerosis were considered. In was observed that using the oscillatory shear index, which is related to the wall shear stress oscillating from its mean direction, did not produce a realistic stenosis development. The other markers produced stenosis growth comparable with observations from the literature.
Original languageEnglish
Article numbere12389
Number of pages16
JournalEngineering Reports
Early online date28 Feb 2021
DOIs
Publication statusEarly online - 28 Feb 2021

Documents

  • eng2.12389

    Final published version, 3.64 MB, PDF document

    Licence: CC BY

Related information

Relations Get citation (various referencing formats)